dc.description.abstractEl estudio consistió en la puesta en marcha y operación de tres reactores anaerobios con manto de lodos y flujo ascendente (Upflow Anaerobic Sludge Blanket, por sus siglas en inglés UASB), durante 14 semanas, con diferentes tiempos de retención hidráulica (TRH) dentro del rango desde las 5 hasta las 9 h, los resultados obtenidos sugieren que para tratar agua residual doméstica no necesariamente se requiere trabajar en el límite máximo del TRH, ya que, en términos de demanda química de oxígeno (DQO), los resultados indican que éstos son capaces de remover materia orgánica, con mejor desempeño cercano al límite inferior del rango reportado como óptimo para su operación (5 h). Además, se monitoreó el comportamiento de los parámetros básicos: oxígeno disuelto (OD), temperatura y pH (potencial de hidrógeno), tanto ambiental, como en el sistema. El proceso desde el punto de vista de la temperatura es un proceso mesofílico, porque ésta osciló en el rango desde los 20ºC hasta 32o Ces_MX
dc.description.abstractThe study consisted of the implementation and operation of three reactors with anaerobic sludge blanket and upstream (Upflow Anaerobic Sludge Blanket, for its acronym in English UASB) for 14 weeks with different hydraulic retention time (HRT) within the range of 5 to 9 h, the results suggest that to treat domestic wastewater is not necessarily required to work the upper limit of HRT, because in terms of COD, indicate that these are capable of removing organic matter, best performing near the lower limit of the range reported as optimal for operation (5 h), plus monitoring the behavior of the basic parameters: DO, temperature and pH, both environmentally, and in system. The process from the standpoint of temperature is a mesophilic process, because it varied in the range of 20°C to 32 ºC.es_MX
dc.formatpdfes_MX
dc.language.isospaes_MX
dc.publisherUniversidad de Ciencias y Artes de Chiapas
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0es_MX
dc.subjectTiempo de Retención Hidráulicaes_MX
dc.subjectreactores anaerobioses_MX
dc.subjectagua residuales_MX
dc.subjectHydraulic Retention Timees_MX
dc.subjectwastewateres_MX
dc.subjectanaerobic reactorses_MX
dc.subject.classificationBIOLOGÍA Y QUÍMICAes_MX
dc.subject.otherBiologíaes_MX
dc.titleComportamiento de reactores anaerobios de flujo ascendente y manto de lodos a diferentes tiempos de retención hidráulicaes_MX
dc.typeArtículoes_MX
dc.identificator2es_MX
dc.audiencegeneralPublices_MX
dc.rights.accessopenAccesses_MX
dc.type.conacytarticlees_MX


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

http://creativecommons.org/licenses/by-nc-nd/4.0
Excepto si se señala otra cosa, la licencia del ítem se describe como http://creativecommons.org/licenses/by-nc-nd/4.0